Hi-Purity Water Systems

Pharmaceutical-grade water generation and distribution systems compliant with cGMP, WHO, and USFDA standards

Water Generation Systems

Complete solutions for purified water, highly purified water, and water for injection

In short: A Hi-Purity Water System treats and distributes pharmaceutical-grade water — Purified Water, Highly Purified Water, or Water for Injection — using RO+MIXBED, RO+EDI, or distillation technology, built and validated to cGMP, WHO, and USFDA standards. Process Pulse designs, supplies, and commissions these systems for pharmaceutical, biotechnology, and healthcare facilities from Vadodara, Gujarat.

RO + MIXBED Systems

Traditional approach combining reverse osmosis with mixed bed ion exchange technology for high-purity water production.

  • Pre-treatment filtration
  • Multi-stage RO system
  • Mixed bed polishing
  • Conductivity monitoring
  • Automated regeneration
  • USP/EP compliance

RO + EDI Systems

Modern continuous deionization technology using electrodeionization for consistent high-quality water production.

  • Continuous operation
  • No chemical regeneration
  • Low operating costs
  • Environmental friendly
  • Stable water quality
  • Minimal maintenance

WFI Systems

Water for Injection generation through distillation or hot water methods meeting stringent pharmaceutical requirements.

  • Multi-effect distillation
  • Vapor compression
  • Hot water sanitization
  • Endotoxin control
  • TOC monitoring
  • FDA/EMA compliant

Water Distribution Systems

Efficient and compliant water storage and distribution solutions

Loop Distribution

Continuous circulation loop systems preventing water stagnation and maintaining consistent quality throughout the facility.

Hot Water Systems

Sanitizable hot water distribution maintaining temperatures above 65°C to prevent microbial growth.

Storage Tanks

SS316L storage vessels with spray ball cleaning systems, vent filters, and level monitoring.

Use Point Valves

Hygienic sampling valves and diaphragm valves designed for pharmaceutical water applications.

Distribution Pumps

Sanitary centrifugal pumps with mechanical seals and CIP/SIP capability.

UV Sanitization

Point-of-use UV units for continuous microbial control in distribution loops.

Technical Specifications

Typical treated-water performance parameters

< 0.1 µS/cm

Conductivity (RO+EDI)

< 0.25 EU/ml

Endotoxin Level (WFI)

< 500 ppb

Total Organic Carbon

80-85°C

Hot Water Circulation

Applications

Versatile solutions for multiple pharmaceutical processes

Injectable Manufacturing

WFI for sterile product formulation and washing

Oral Solid Dosage

Purified water for granulation and coating

Topical Products

High-purity water for creams and ointments

API Production

Process water for active ingredient synthesis

Laboratory Testing

Reagent-grade water for analytical procedures

Equipment Cleaning

CIP/SIP applications in production areas

Pharmacopoeial Water Quality Limits

What Purified Water and WFI must meet under USP and Ph. Eur.

Pharmaceutical water is defined by pharmacopoeial monographs, not by the treatment technology used to make it. A system is designed backwards from these limits, with margin, so that water at every point of use stays within specification between sanitisation cycles.

  • Conductivity: no more than 1.3 µS/cm at 25 °C (USP <645> stage 1) for Purified Water and WFI
  • Total Organic Carbon (TOC): no more than 500 ppb (USP <643>)
  • Microbial action levels: typically 100 CFU/mL for Purified Water and 10 CFU/100 mL for WFI (USP <1231> guidance)
  • Bacterial endotoxins: less than 0.25 EU/mL for Water for Injection
  • Highly Purified Water (Ph. Eur.) meets WFI chemical and microbial quality but may be produced by non-distillation methods

Choosing the Right Generation Technology

RO+EDI, RO+Mixed Bed or distillation — how to decide

RO+EDI is the usual first choice for Purified Water in new facilities. Electrodeionisation polishes RO permeate continuously, with no acid or caustic regeneration, which removes chemical handling from the water room and keeps quality stable.

RO+Mixed Bed has a lower capital cost and suits smaller or intermittent demand, but needs periodic regeneration or resin replacement and shows a gradual rise in conductivity as resin exhausts.

For Water for Injection, multi-effect distillation and vapour compression remain the established route. Since April 2017 the European Pharmacopoeia also allows WFI produced by reverse osmosis combined with techniques such as EDI and ultrafiltration — an option that can cut energy use, but which needs a robust sanitisation and monitoring strategy.

The right answer depends on feed water analysis, required capacity and peak draw, the water grades needed, the target markets' pharmacopoeias, and utility costs on site.

Storage and Distribution Design Principles

Where most microbial problems actually start

A generation system can produce excellent water that is then spoiled in storage and distribution. Good loop design keeps water moving, hot or regularly sanitised, and free of places where biofilm can form.

  • Continuous circulation with turbulent flow — loops are commonly designed for a return velocity of around 1 m/s or more
  • Minimal dead legs — current ISPE guidance targets branches no longer than about three pipe diameters (3D), tighter than the older 6D rule
  • Hot storage and circulation (typically 65–85 °C) for WFI, or ambient loops with scheduled thermal, ozone or chemical sanitisation for Purified Water
  • Where ozone is used in ambient storage, UV at 254 nm before the points of use destroys residual ozone
  • Orbital-welded SS 316L tubing with suitable internal surface finish, sloped for full drainability, with sanitary diaphragm valves at points of use
  • Online conductivity and TOC monitoring on the return line, plus defined sampling points for microbial testing

Qualification and Validation

DQ, IQ, OQ and the three phases of PQ

Pharmaceutical water systems are qualified in stages. Design Qualification confirms the design meets the user requirement specification; Installation Qualification verifies materials, welds, slopes and instruments as installed; Operational Qualification tests alarms, interlocks and sanitisation cycles.

Performance Qualification follows the phased approach described in WHO and FDA guidance: intensive daily sampling for about 2–4 weeks, a further 2–4 weeks confirming consistent operation under SOPs, and one year of routine monitoring to capture seasonal changes in feed water. Systems are supplied with the DQ/IQ/OQ/PQ documentation needed to support this, aligned with WHO good practices for pharmaceutical water and India's revised Schedule M.

Hi-Purity Water System FAQs

Common questions on specifications, technology and validation

What is the conductivity limit for Purified Water?

Under USP <645> stage 1, Purified Water and Water for Injection must have a conductivity of no more than 1.3 µS/cm at 25 °C. Well-designed RO+EDI systems typically produce water well below that limit.

What is the TOC limit for pharmaceutical water?

Total Organic Carbon (TOC) for Purified Water and WFI must not exceed 500 ppb (0.5 mg/L) under USP <643> and the equivalent Ph. Eur. test.

Can Water for Injection be made without distillation?

Yes. USP has long allowed WFI to be produced by distillation or an equivalent purification process, and since April 2017 the European Pharmacopoeia also permits WFI produced by reverse osmosis combined with other suitable techniques such as EDI and ultrafiltration, subject to appropriate controls.

Should I choose RO+EDI or RO+Mixed Bed?

RO+EDI is usually preferred for new pharmaceutical systems: it runs continuously without acid and caustic regeneration and gives stable water quality. RO+Mixed Bed has a lower capital cost and suits smaller or intermittent demand, but needs periodic chemical regeneration or resin replacement.

How long does water system validation take?

Performance qualification is normally done in three phases: about 2–4 weeks of intensive daily sampling (phase 1), a further 2–4 weeks confirming consistent operation under SOPs (phase 2), and one year of routine monitoring to capture seasonal variation in feed water (phase 3).